Mounting wires are designed for operation at rated alternating voltage 600 and 1400 V with up to 10000 Hz frequency and direct voltage up to 840 and 1400 V accordingly in electrical devices connections for general industrial use.
Wire models and their definitions shall correspond to the details given in the table below:
Model | Definition |
НВ | mounting wire with copper tinned wire conductor, PVC compound insulated. |
НВЭ | mounting wire with copper tinned wire conductor, PVC compound insulated, shielded. |
НВМ | mounting wire with copper wire conductor, PVC compound insulated. |
НВМЭ | mounting wire with copper wire conductor, PVC compound insulated, shielded. |
- tinned,copper, stranded for НВ, НВЭ models;
- copper, strandedfor НВМиНВМЭ models.
INSULATION: PVC compound. Insulation is colored solid or in stripes.
SHIELDING:tinned copper wire braiding for НВЭ model; copper wire braiding forНВМЭmodel. Braiding coverage - not less than 70%.
NUMBER OF CONDUCTORS:1 forНВ, НВМ; 1,2,3 forНВЭ, НВМЭ.
CONDUCTORAREA, mm²:0.12; 0.20; 0.35; 0.50; 0.75; 1; 1.5; 2.5.
Rated alternating voltage, V:
Model | Number of conductors | Rated conductor area, mm² | Rated alternating voltage, V |
НВ, НВМ | 1 | 0.12; 0.20; 0.35; 0.50; 0.75; 1.00; 1.5; 2.5. | 600 and 1000 |
НВЭ | 1,2,3 | 0.12; 0.20; 0.35; 0.50; 0.75; 1.00; 1.5; 2.5. | |
НВМЭ |
1,2,3 | 0.12; 0.20; 0.35; 0.50; 0.75; 1.00 | 600 |
1 | 0.12; 0.20; 0.35; 0.50; 0.75; 1.00; 1.5; 2.5. | 1000 | |
2;3 | 0.12; 0.20; 0.35; 0.50; 0.75; 1.00 |
Electrical wire insulation resistancefor a length of 1 m shall be not less than 1x104 MΩ.
Wires are resistant to vibrations, shocks, exposure to gasoline, oils and mold.
Wires do not spread combustion when single laid.
Operating temperature range: from -50°С to +105°С.
Factory length:
- unshielded wires - 50m;
- shieldedwires - 20 m.
Operational life of wires - not less than 15 years.