Motor-and-tractor wires with polyvinylchloride insulation

2 Motor-and-tractor wires with polyvinylchloride insulation
Motor-and-tractor wires with polyvinylchloride insulation

ПВА, ПВАЭ, ПГВА, ПГВА-ХЛ, ПГВАЭ, ПГВАнг(С), ПГВАЭнг(С), ПГВАМ, ПВАМ, ПВАМ-1 under Technical Specificationsof The Republic of Belarus 05755944.013-98, Technical Specifications16.К17.021-94, echnical Specificationsof The Republic of Belarus 05755944.012-98, Technical Specifications 16.К17.030-97

Request a commercial offer
Лого

1. Designation

Motor-and-tractor wires with polyvinylchloride insulation (hereinafter - "wires") are designed for motor-and-tractor equipment connection to electrical equipment with rated voltage up to 28 V, manufactured for vehicles designed for usage in moderate, tropical and frigid climate.

2. Construction

Wire models, their primary operation area and temperature range of usage as components of harnesses and armored cables correspond to the requirements given in the table below:

Model Definition Primary operation area temperature range of usage °С
ПВА Wire of high flexibility with copper conductor, polyvinylchloride (PVC) insulated, single-wired, heat-resistant Motor-and-tractor equipment and devices requiring high connection flexibility and operating at high temperatures from -40°С to +105°С 
ПВАЭ Wire of high flexibility with copper conductor, polyvinylchloride (PVC) insulated, single-wired, heat-resistant, shielded The same as above but additionally requiring wire shielding The same
ПВАМДЭ Wire of high flexibility with copper conductors, polyvinylchloride insulated, double-wired, shielded, with polyvinylchloridesheath, heat-resistant The same as above but additionally requiring wire shielding The same
ПГВА Wire of high flexibility with copper conductor, PVC insulated, single-wired For motor-and-tractor equipment connection to electrical devices and equipment from -40°С(from -60°С in compliance with ХЛ1) to +80°С
ПГВАЭ Wire of high flexibility with copper conductor, PVC insulated, single-wired, shielded The same as above but additionally requiring wire shielding Thesame
ПГВАнг(С) Flexible wirewithcopperconductor, PVCinsulated, fire-resistant,single-wired For motor-and-tractor equipment connection to electrical devices and equipment from -40°С to +70°С 
ПГВАЭнг(С) Flexible wirewithcopperconductor, PVCinsulated, fire-resistant,single-wired, shielded The same as above but additionally requiring wire shielding Thesame
ПГВАМ Flexible wire with copper conductor, PVC thin-wall insulated, single-wired For motor-and-tractor equipment connection to electrical devices and equipment from -40°С to +80°С 

CONDUCTOR:copper, stranded.

INSULATION:forПГВА, ПГВАМ, ПГВАЭ models- PVC compound;

forПВА, ПВАЭ, ПВАМДЭ, ПВАМ-1 models - heat-resistant PVC compound;

forПГВА, ПГВАЭmodelsofХЛ1 type -frost-resistantPVC compound;

forПГВАнг(С), ПГВАЭнг(С) models- fire-resistant PVCcompound.

For ПВАМand ПГВАМ models thin-wall insulation is used. Wire insulation can have solid color or combined color (by order). Combined coloring is performed by combining parallel strips of two colors, one of which is basic. There should be one or two secondary colorstrips.

SHIELDING:in wires of ПВАЭ, ПГВАЭиПГВАЭнг(С) models the insulated conductors are covered with shielding - braiding with copper wire of 0.12 mmto 0.26 mm rated diameter, tinned with tin-lead solder. For ПГВАЭ, ПВАЭиПГВАЭнг(С) models of type Т1 the shielding copper wire is tinned with tin solder. ПВАМДЭ model shielding consists of braiding or winding of copper wire or winding with foiledpolyethyleneterephthalate (lavsan) tape covering.

NUMBER OF CONDUCTORS:1. ForПВАМДЭ model - 2.

CONDUCTORAREA, mm²:0.35; 0.50; 0.75; 1.0; 1.2; 1.5; 2.0; 2.5; 3; 4; 5; 6; 8; 10; 16; 25; 35; 50; 70; 95.

3. Technical specifications

WiresofПВА, ПВАЭ, ПГВА, ПГВАЭ, ПГВАМ, ПГВАнг(С), ПГВАЭнг(С) modelsareresistanttotheeffectoflowambienttemperature: -40°С; ПГВА, ПГВАЭmodels of typeХЛ1: -60°С.

The wires have thermal stability.

The wires are resistant to the effects of temperature changes:

а) ПВА, ПВАЭ, ПВАМmodels: from -40°Сto +105°С;

б) ПГВА, ПГВАЭ, ПГВАМmodels: from -40°С to +80°С;

в) ПГВА, ПГВАЭmodelsoftypeХЛ1: from -60°С to +80°С;

г) ПГВАнг(С), ПГВАЭнг(С) models: from -40°Сto +70°С;

д) ПВАМ-1 model: from -40°Сto +125°С.

Wires of ПГВАМ, ПВА, ПВАЭ, ПГВА, ПГВАЭ, ПГВАнг(С), ПГВАЭнг(С) oftypeХЛ1 models are resistant to mold damage.

Wires are resistant to shocks, winding, bending, cracking, vibrations, exposure to gasoline, mineral oil and mold.

Wires ofПГВА, ПГВАЭ, ПГВАМ, ПВА, ПВАЭ, ПВАМ, ПВАМ-1 models do not spread combustion when single laid; modelsПГВАнг(С), ПГВАЭнг(С)do not spread combustion when laid as harness.

Factory cable length is not less than 100 m.

Cables operational life is not less than 10 years.